Chantier Irrigal

Product Datasheet Search

Anchored solutions for the CLASSIC range - DN 700 to 1800

Technical solutions

Anchoring solutions for the CLASSIC range - DN 700 to 1800

The CLASSIC ductile iron pipeline range comprises:

Pipes :
- With 200g/m2 external coating of pure zinc (99,99%) and a coat of varnish.
- With STANDARD joint, class C30 DN 700 to 1000, class C25 DN 1100 to 2000 .
- With UNIVERSAL Ve joint, class C30 DN 700 to 1000, class C25 DN 1200 to 1600.
- With PAMLOCK joint, class C25 DN 1400 to 2000.

Fitting :
- With EXPRESS, STANDARD, UNIVERSAL and PAMLOCK with epoxy coating deposited by cataphoresis or bituminous coating (in compliance with EN 545).
- With STANDARD, UNIVERSAL and PAMLOCK joints with epoxy powder or spray coating (in compliance with EN 14 901).

The CLASSIC range's durability is considerably greater than that of cast iron pipelines with only a 130 g/m2 zinc coating as prescribed by standard EN 545 owing to the thicker application of zinc at 200 g/m2.

The anchoring solutions for the CLASSIC range, DN 700 to 2000

UNIVERSAL Ve - for large diameters

For UNIVERSAL pipes and fittings, DN 700 to 1600.

PAMLOCK - for very large diameters

For UNIVERSAL pipes and fittings, DN 1400 to 2000.

STANDARD Ve - for large diameters

STANDARD Ve supplementary solution for STANDARD Ve pipes and fittings, DN 700 to 1200.

For aggressive situations, the following pipeline
systems :

TT PE or TT PUX for aggressive soils

Suitable for very corrosive soils or when there are stray currents (PE, polyethylene with diameter DN 700, in compliance with standard EN 14628, and PUX, polyurethane in compliance with standard EN 15189 with DN from 800 to 2000) (See standard EN 545 appendix D.2 to check when it is advisable to use this external coating).

PUR for aggressive water

Suitable to carry water that is aggressive to cement mortars (See standard EN 545 appendix E to check when it is advisable to use this internal lining).
The PUR solution has an internal polyurethane coating in accordance with standard EN 15655.

 CLASSICCLASSICPURTT PE-PUXUNIVERSAL PUR
PAMLOCK PUR
UNIVERSAL TT PE-PUX
PAMLOCK TT PUX
Field of useAll soils barring exceptionsAggressive
water
Aggressive
soils
High
pressures
Aggressive
soils
High
pressures
JonctionSTANDARDSTANDARDSTANDARDSTANDARDUNIVERSALUNIVERSAL
PipeDN 700 - 2000-DN 700 - 2000DN 700 - 2000DN - 1200 UNI Ve
DN 1400 - 2000 PAMLOCK
BendDN 700 - 2000DN 700 - 1200DN 700 - 2000DN 700 - 1200 UNI Ve
DN 1400 - 1800 PAMLOCK
TaperDN 700 - 2000DN 700 - 1200DN 700 - 2000DN 700 - 1200 UNI Ve
DN 1400 - 1800 PAMLOCK
Sleeve-DN 700 - 1200--
Tee, 2- socket (EB)DN 700 - 2000
PN10, PN16, PN25
DN 700 - 1200
PN10, PN16, PN25
DN 700 - 2000
PN10, PN16, PN25
DN 700 - 1200 UNI Ve
DN 1400 - 1800 PAMLOCK
Tee, 3-socket (E)-DN 700 - 1200DN 700 - 2000-
Drain teeDN 700 - 2000DN 700 - 1200DN 700 - 2000-
Flanged
socket
DN 700- 2000DN 700 - 1200DN 700 - 2000DN 700 - 1200 UNI Ve
DN 1400 - 1800 PAMLOCK
Flanged
spigot
DN 700 - 2000DN 700 - 1200 Uni Ve
DN 1400 - 1800 PAMLOCK
Blank
flange
DN 700 - 2000DN 700 - 2000
Reducing
flange
DN 700 - 2000
PN10, PN16, PN25
DN 700 - 2000
PN10, PN16, PN25
Non-anchored
joint
STANDARDEXPRESSSTANDARD-
Anchored
joint
STANDARD Ve
700 - 1200
-STANDARD Ve
700 - 1200
DN 700 - 1200 UNI Ve
DN 1400 - 1800 PAMLOCK

 

Technical specifications of CLASSIC range DN 700 to 2000

 STANDARDUNIVERSAL
PAMLOCK
TT
UNIVERSAL TT
PAMLOCK TT
PUR
Pipes EN 545
  • External coating: Zn, 200g/m2 + bituminous varnish sealer
  • Internal lining: blast furnace cement mortar
  • External coating: Zn, 200g/m2 + bituminous varnish sealer
  • Internal lining: blast furnace cement mortar
  • External coating: Zn + coat of HDPE on DN 700 in compliance with EN 14628
  • External coating: polyurethane on DN 800 to 2000 in compliance with EN 15189
  • Internal lining: blast furnace cement mortar
  • External coating: Zn, 200g/m2 + bituminous varnish sealer
  • Internal lining: polyurethane in compliance with EN 15655
Fittings EN 545
  • Epoxy coating deposited by cataphoresis, or bituminous coating
  • Epoxy coating deposited by cataphoresis, or bituminous coating
  • Epoxy powder coating in compliance with EN 14901
  • Epoxy powder coating in compliance with EN 14901
Attaching
hardware
EN 545
  • Epoxy coating deposited by cataphoresis
  • Without bolt
  • Without bolt
 

Important supplementary information

Angular deflection

Ensure compliance with the maximum angular deflection specified in the table, and note the angular deflection of anchored joints is generally slightly less than that of joints that are not anchored.

Fittings

The UNIVERSAL and PAMLOCK fittings ranges are not as extensive as the STANDARD joint ranges. All the possibilities offered by the STANDARD range can be obtained by combining UNIVERSAL or PAMLOCK fittings with flanged fittings.

Tee fittings

The pressure resistance of tees with tube diameters greater than DN 600 is lower than that of the pipes. Please consult us for further information.

Higher pressure

For pressures higher than those specified in the table, please consult us.

See also

PAM’s anchoring solutions are designed according to two different levels of performance, plus a supplementary range to cater for some specific situations.