The NATURAL ductile iron pipeline range comprises:

  • Pipes :

With 400 g/m2 external coatings of 400 zinc (85%) and aluminum (15%) alloy and a coat of light blue epoxy.
Pressure class C40, DN 60 to 300, and C30, DN 350 to 600, with STANDARD joint.
Pressure class C30 DN 700 to 1000, and C25 DN 1200 to 1600 with UNIVERSAL joint.

  • Fittings :

With EXPRESS and STANDARD joints with epoxy coating deposited by cataphoresis (in compliance with EN 545).
With STANDARD or UNIVERSAL joints with epoxy powder coating (in compliance with EN 14901).

The NATURAL range's durability and scope of use are considerably greater than those of cast iron pipelines with only a 130 g/m2 zinc coating as prescribed by standard EN 545.

The anchoring solutions in the NATURAL range

STANDARD Vi and EXPRESS Vi – For most common situations

STANDARD Vi for pipes, DN 60 to 600 and STANDARD fittings, DN 350 to 600.
EXPRESS Vi for fittings, DN 60 to 300.

UNIVERSAL Vi – For very high pressures

For UNIVERSAL pipes and fittings, DN 80 to 600.

UNIVERSAL Ve – For extreme pressures

For UNIVERSAL pipes and fittings, DN 100 to 600.

For aggressive situations, the following pipeline :

TT for aggressive soils

Suitable for very corrosive soils or when there are stray currents (See standard EN 545 appendix D.2 to check when it is advisable to use this external coating).
The STANDARD TT-PE solution has a thick extruded polyethylene coating in accordance with European standard EN 14628. This is the most commonly used solution in this range.

NATURAL PUR for aggressive water

Suitable to carry water that is aggressive to cement mortars (See standard EN 545 appendix E to check when it is advisable to use this internal coating).
The PUR solution has an internal polyurethane coating in accordance with standard EN 15655.

 NATURALNATURALNATURAL PURTT-PENATURAL UNIVERSALUNIVERSAL TT-PE
Field of use
 
All soils barring exceptionsAggressive
water
Aggressive
soils
High
pressures
High pressures
Aggressive soils
JonctionSTANDARDEXPRESSSTANDARDSTANDARDUNIVERSALUNIVERSAL
PipeDN 60 - 600DN 100, 150, 200, 250, 300DN 100 - 600DN 60 - 600DN 80 - 600
Uni Vi - Uni Ve
DN 80 - 600
Uni Vi - Uni Ve
BendDN 350 - 600DN 60 - 600DN 60 - 600DN 80 - 600
TaperDN 350 - 600DN 60 - 600DN 60 - 600DN 100 - 600
Sleeve-DN 60 - 600--
Tee, 2- socket (EB)DN 350 - 600 
PN10, PN16, PN25
DN 60 - 600
PN10, PN16, PN25
DN 60 - 600
PN10, PN16, PN25
DN 80 - 600
PN10, PN16, PN25
Tee, 3-socket (E)DN 350 - 600DN 60 - 600DN 60 - 600DN 100 - 300
Drain teeDN 350 - 600DN 60 - 600DN 60 - 600-
Flanged
socket
DN 350 - 600DN 60 - 600DN 60 - 600DN 80 - 600
Flanged
spigot
DN 60 - 600DN 60 - 600
Non-anchored, STD Vi and UNI Vi - Anchored
joint: UNI Ve
Blank
flange
DN 60 - 600DN 60 - 600
Reducing
flange
DN 100 - 600
PN10, PN16, PN25
DN 60 - 600
PN10, PN16, PN25
Non-anchored
joint
DN 60 - 600DN 60 - 600DN 60 - 600DN 80 - 600
Anchored
joint
DN 60 - 600DN - 300DN 100 - 600DN 60 - 600DN 80 - 600
Uni Vi - Uni Ve

Technical specifications of NATURAL range, DN 60 to 600

 NATURALNATURAL
UNIVERSAL
TT
UNIVERSAL TT
NATURAL
PUR
Pipes
EN 545
  • External coating:
    400 g/m2 Zn/Al 85/15
    + blue epoxy + sealer
  • Internal lining:
    blast furnace cement
    mortar
  • External coating:
    400 g/m2 Zn/Al 85/15
    + blue epoxy + sealer
  • Internal lining:
    blast furnace cement
    mortar
  • External coating:
    Zn + coat of HDPE
    in compliance with
    EN 14628
  • Internal lining:
    blast furnace cement
    mortar
  • Revêtement extérieur Zn/A185/15 à 400 g/m² + bouche-pore époxy bleu
  • Revêtement intérieur polyuréthane selon EN 15655
Fittings
EN 454

 
  • Epoxy coating deposited
    by cataphoresis
  • Epoxy powder coating
    in compliance with
    EN 14901
  • Epoxy powder coating
    in compliance with
    EN 14901
  • Epoxy powder coating
    in compliance with
    EN 14901
Attaching
hardware EN 545
  • Epoxy coating deposited
    by cataphoresis
  • Without bolt
  • Without bolt
  • Epoxy coating deposited
    by cataphoresis

Important supplementary information

Angular deflection

Ensure compliance with the maximum angular deflection specified in the table, and note the angular deflection of anchored joints is generally slightly less than that of joints that are not anchored.

Fittings

UNIVERSAL fittings are not available in DN 350 and 450. STANDARD V+I anchoring fittings should be used with UNIVERSAL Vi pipes, and STANDARD Ve fittings should be used with UNIVERSAL Ve pipes in these 2 DN.

Combined use of NATURAL STANDARD and NATURAL UNIVERSAL pipes

When performing cutting operations on site, be sure to distinguish cuts performed on UNIVERSAL pipes from cuts made on STANDARD pipes (by applying paint to mark cuts on UNIVERSAL pipes, for example). Only UNIVERSAL cut sections can be fitted in UNIVERSAL sockets with the anchoring pressure levels specified in the table.

NATURAL PUR

See the NATURAL PUR range.

See also

PAM’s anchoring solutions are designed according to two different levels of performance, plus a supplementary range to cater for some specific situations.